Using the app
A tour of the window, then a first roll from start to finish. You need the scanner built, wired and flashed (build guide, steps 1 to 6) and the app installed (installation).
The pictures come from the tests’ simulated scanner: grey squares for film, and a stand-in for an X-T5.
- The window
- Connect the camera and the scanner
- Choose the film
- Test the motor and servo
- Move the film
- Check the framing
- Name the roll
- Calibrate
- Scan
- When the scan pauses
- The next strip, and quitting
- Convert negatives
- Keyboard shortcuts
1. The window
Section titled “1. The window”
Calibrated and ready to scan. Red marks the gaps between frames, green the frame’s center; the line under the picture says how far the frame is from the middle.
| Where | What is there |
|---|---|
| Top bar | Scan and Convert; Camera and Scanner (with a list of ports); Refresh, Shortcuts, Quit. Version X.Y.Z is out opens a newer version’s download page (updating) |
| Left | Film, Roll (name, file name, folder, number of frames, first number) and Setup (calibration, hardware test). Kept between sessions |
| Middle | The live view, with what the scanner found drawn on it, and zoom buttons. Under it, the film controls, and Check framing for a camera without a live view |
| Right | Scan: the frame counter, a checklist of what is missing, Start scan, the Activity log |
A greyed-out button is waiting for the scanner, the camera, a calibration, or the current task to end. The checklist says which.
2. Connect the camera and the scanner
Section titled “2. Connect the camera and the scanner”Plug in the Arduino and the camera, on and in its tethered-shooting USB mode (setting up the camera). Then open Rollscan, or press Refresh if it is already open.
- Camera shows the model, or Not found. Any camera but the Fujifilm X-T5 is marked (untested): it may work, nobody has tried yet.
- Scanner shows the Arduino’s port. If several are listed, pick the Arduino’s.
The checklist turns green line by line: Camera connected, Scanner connected, then the calibration (step 8). Still Not found? See troubleshooting.
3. Choose the film
Section titled “3. Choose the film”Under Film:
- 35mm or 120: the film bed and roller on the scanner.
- Frame size: 36 × 24 or Panoramic for 35mm; 6 × 4.5, 6 × 6, 6 × 7 or 6 × 9 for 120. It sets the advance, and must match the scanner’s pressure frame.
- Film type: Negative or Slide. The gaps between frames are the brightest part of a negative, the darkest of a slide.
4. Test the motor and servo
Section titled “4. Test the motor and servo”Open Setup, bottom left, and press Test motor & servo. No camera needed.

The Activity log says what you should have seen, and what to check if nothing moved.
The pressure frame lifts twice; the film moves a little forward, then back. Nothing moved? Check every GND wire, then the power jumper on the ULN2003 board, then the servo’s signal wire on D9 (troubleshooting).
Run it after building the scanner, and whenever the film stops moving.
5. Move the film
Section titled “5. Move the film”To load a strip, lift the pressure frame, lay the film with the sprocket’s teeth in the perforations (on 120, the roller’s O-rings on the film’s margins), and lower the frame.
Each button under the picture lifts the pressure frame, moves the film, and lowers it.
| Button | Moves | Keyboard |
|---|---|---|
| Outer pair | One whole frame, back or forward | Shift + Left, Shift + Right |
| Inner pair | The length picked between them, back or forward | Left, Right |
| .25, .5, 1, 2, 5, 10 | Pick that length, in millimetres | Up for a longer one, Down for a shorter one |
The length is remembered. Keys work whenever you are not typing in a field.
Zoom with the mouse wheel, the + and - buttons at the top right of the picture, or a double click. Drag to move around; the percentage between - and + shows the whole picture again.
On the scanner, hold FWD or BACK to move the film, or press FRAME to advance one frame. Never press FRAME during a scan (step 9).
6. Check the framing
Section titled “6. Check the framing”The live view shows what the scanner finds (picture in step 1):
- Red boxes: the gaps the frame was placed by. Fainter boxes: bright bands it ignored.
- Green lines: the frame’s edges and center.
- White line: the middle of the picture.
Under it: Frame found, 12 px left of the center, Frame found, centered, Frame not found or No film in view.
Aim for the strip running left to right, the whole frame in view with a little gap each side, and a red box on each gap. No red boxes usually means the gaps are out of view or the exposure is off (the frame isn’t found).
The live view freezes a few seconds at each shot. If it stops, the picture says so: check the camera, then press Refresh.
Without a live view, the picture is the last shot, and Check framing appears by the film controls. It shoots once, draws the same marks, and the Activity log gives the frame’s offset in pixels, or says it wasn’t found. That shot is not saved.
7. Name the roll
Section titled “7. Name the roll”Under Roll:
- Name: the roll. A calibration is made for the roll of that name (step 8), so name it first.
- File name (optional): starts every file name; empty, it is the roll’s name.
parisgivesparis_01.jpg,paris_02.jpgand so on, plus each RAW file if the camera records RAW+JPEG. The first names show under the field. Change this, not the roll’s name, to rename files without calibrating again. - Saved in: the folder. Change opens a folder picker (it can create folders);
Show scans in the file manager opens it. It starts as
Pictures/film-scansin your home folder (Pictures/Film scanson Windows). - Frames: frames on the strip, 1 to 99; 36 or 24 for an uncut roll. Too many is fine: the scan stops at the end of the strip.
- First number: the first file’s number. 1 for a new roll; 7 for the second strip of a roll cut in sixes.
The app never overwrites a scan: if a file name is taken, the scan won’t start and asks you to change the file name or the first number.
8. Calibrate
Section titled “8. Calibrate”Calibration measures how far the picture moves per motor step, how wide a frame is, and how clear this film’s bare base is. Start scan stays greyed out until it is done.
Open Setup and press Calibrate. Two steps follow, shown under the picture.
1. The film’s base, which the scanner uses to find the gaps. Show it bare film:
- unexposed film (a blank frame at a roll’s end), then Measure this blank frame;
- or a rectangle drawn inside a gap, clear of both pictures, then Measure what I drew;
- or neither: Skip: learn it while scanning.

A rectangle drawn in yellow inside the gap on the left, ready for Measure what I drew.
2. A frame. Bring a frame with a picture roughly to the middle, the whole height of the pressure frame’s window in view, and press Calibrate. The app looks four times, moving the film forward twice and back once, then returns it near where it was. Cancel keeps the old calibration.
Done: Setup and the checklist say Calibrated for 35mm 36 × 24, with the date and how the base was found; the checklist’s last line turns green, and the button reads Calibrate again. The Activity log gives the measured numbers.
Calibrate again when you change:
- the film or the roll’s name (the checklist then says Calibrated for another film);
- the lens, camera height, magnification, exposure or lamp;
- the format: Setup opens by itself with calibrate again for ….
The picture only moved … px means the film did not follow the motor: check it is loaded, perforations on the sprocket.
9. Scan
Section titled “9. Scan”- Line up the first frame until the line under the picture says it is found and near the center.
- Press Start scan.
Each frame is found, nudged to the center, shot, and the film advances. With a live view that costs one photo per frame. Without one, an off-center shot is deleted and retaken: about 12 seconds per frame on an X-T5.

The counter and Activity log follow each saved frame; the left side is locked.
While it runs:
- The counter shows the frames saved; the picture keeps showing the film.
- The Activity log reports each frame: saved, only roughly centered, nothing here (blank frame?).
- The settings on the left are locked, and the window cannot be closed.
- Stop scan replaces Start scan. It stops after the current frame; what was saved stays.
- Do not press FRAME on the scanner. The Arduino would advance on its own; the app notices, but that frame may be skipped.
The scan ends after the frames you asked for, or at the end of the strip: one empty position is skipped as a blank frame, two in a row end the film. The log says Done, with the file count and folder. For negatives, Convert the N negatives opens Convert with the scan’s RAW files.
The first frames need the most corrections. Once the scanner has learned the frame spacing of the camera that shot the roll, a few frames in, most are centered at once.
10. When the scan pauses
Section titled “10. When the scan pauses”A frame the scanner can’t find (very dark, very thin, or edges lost in the gaps) pauses the scan: Frame 12 wasn’t found. Line it up with the arrows below, then shoot it.

Frame 5 has no gap the scanner can see: the scan waits for you.
- Center the frame by eye with the film controls.
- Press Shoot it (or Enter). The shot is kept as is, and the scan goes on.
Or press Stop scan.
This film’s base looks different means the film is clearer than the calibrated base (another film or exposure). Go on with a guess guesses the base from each picture; Stop scan lets you calibrate again.
won’t center … calibration may be stale in the log: the corrections no longer bring the frame to the middle. Stop, calibrate again, and restart from that frame with First number.
11. The next strip, and quitting
Section titled “11. The next strip, and quitting”Next strip of the same roll: load it, line up its first frame, set First number to the number after the last file and Frames to the strip’s count, and press Start scan. The calibration holds while the film, camera, lens and format stay the same.
New roll: change the Name, set First number to 1, and calibrate.
Quit, top right, releases the camera and the scanner after asking. Use it before uploading firmware or using the camera elsewhere: the open app keeps both.
12. Convert negatives
Section titled “12. Convert negatives”Convert, top left, turns RAW negatives from the scanner into positives, without the camera or the scanner.

A black-and-white negative converted: the tools on the left of the picture, the negatives in a strip under it, the negative’s adjustments on the right.
| Where | What is there |
|---|---|
| Left of the picture | What a click on it does: Move, Film base, Frame, Greys; then Pick a grey, the two turns and the crop |
| Under the picture | What a click does now, the frame’s shape while drawing frames, the zoom |
| Bottom | The negatives, as thumbnails marked converted, adjusted or saved, and what acts on the ones selected |
| Right | This negative: as shot or positive, the histogram, the warnings and the adjustments. All negatives: what is drawn, the colour layers, the clipping, where the files go. Under both, Copy and Save |
Point at any control for a moment to see what it does and its key. The latest scan’s negatives come in by themselves; add others with + or by dropping them on the window. Draw the base and the frame, pick Positive, adjust, and save a 16-bit TIFF in the scans’ folder. Details in Turning a negative into a positive.
13. Keyboard shortcuts
Section titled “13. Keyboard shortcuts”Shortcuts, top right, or ? lists those of the view shown. They pause while you type
in a field.
In Scan:
| Key | What it does |
|---|---|
| Left, Right | Move the film back or forward by the chosen length |
| Up, Down | Choose a longer or shorter length |
| Shift + Left, Shift + Right | Move the film by one frame |
+, - |
Zoom in or out of the picture |
0 |
Show the whole picture |
S |
Start the scan |
| Esc | Stop the scan |
| Enter | Shoot the frame a paused scan is waiting for |
F |
Check the framing (cameras without a live view) |
R |
Refresh: look for the camera and the scanner again |
? |
Show the list |
On the picture, the mouse wheel zooms and dragging pans.
In Convert:
| Key | What it does |
|---|---|
| Left, Right | Show the previous or the next negative |
| Ctrl + click, Shift + click | Select a negative in the strip, or the ones between |
| Ctrl + A, Esc | Select every negative, or none |
Y |
Convert the negative shown, or show it as shot again |
C |
Show only the frame, or the whole picture again |
B, held |
Show the negative as shot, to compare |
S |
Save the positive shown |
H |
Move: a click draws nothing, a drag moves the picture once zoomed in |
1, 2, 3 |
Draw the film base, the frame or greys; Esc goes back to Move |
G |
Pick a grey; Esc stops |
[, ] |
Turn the negative shown a quarter left or right |
+, -, 0 |
Zoom in, out, or show the whole picture |
? |
Show the list |
On the picture, the mouse wheel zooms; with Move, Space held, or the middle button, dragging moves the picture.
Something went differently? See troubleshooting, and how it works for what happens behind each button.